The following LAN messages are reported:
Message Description
Unit is ok PowerLink Broadband Module is functioning correctly.
Test aborted The diagnostic test is aborted, as follows:
• AC failure – PowerLink Broadband Module is set to OFF mode.
• PowerLink Broadband Module has not completed the power-up procedure. In
this case, the installer should wait a maximum of 30 seconds before re-
testing.
Comm. loss The RS-232 serial interface between the PowerLink Broadband Module and the
PowerMaster-10 failed.
Rcvr Ip missing Receivers IP 1 and 2 settings are missing in the PowerMaster-10.
Cable unplugged The Ethernet cable is not connected to the PowerLink Broadband Module.
Check lan config This message appears in any of the following cases:
• Incorrect PowerLink Broadband Module IP has been entered.
• Incorrect subnet mask has been entered.
• Incorrect default gateway has been entered.
• DHCP server failure.
Rcvr#1 UnReach.
Rcvr#2 UnReach.
Receiver 1 or 2 is inaccessible, as follows:
• Wrong receiver IP has been entered.
• Receiver failure.
• WAN Network failure.
Rcvr#1 UnReg.
Rcvr#2 UnReg.
The PowerMaster-10 unit is not registered to IP receiver 1 or 2.
Broadband Module timeout
err.
PowerLink Broadband Module does not respond to test result within 70 sec.
Invalid result PowerLink Broadband Module responds with a result code that is not recognized
by the PowerMaster-10.
5.1.7 LAN Reset Option
1.
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
2.
*
3.
or
4.
REBOOT
LAN RESET OPTION
WL DEVICES
DIAGNOSTICS