PowerMax10
Fully supervised wireless alarm control system
Installer Guide
Vue de la page 0
1 2 3 4 5 6 ... 77 78

Résumé du contenu

Page 1 - PowerMax10

PowerMax10Fully supervised wireless alarm control systemInstaller Guide

Page 2 - PowerMax10-G2

D-302756 9 3. Enter your Installer Code. CODE 4. When the PowerMax10-G2 display reads [NEW INSTL CODE], press OKI. OKI The PowerMax10-G2 display

Page 3

10 D-302756 The PowerMax10-G2 display reads [NEW MASTER CODE] and a "Happy Tune" ☺ sounds to confirm the new MASTER INSTALLER code. You c

Page 4

D-302756 11 To Configure Permissions for System Reset after an Alarm Event 1. Make sure the system is disarmed and then press the button repeatedl

Page 5 - 3. INSTALLATION

12 D-302756 The PowerMax10-G2 display reverts to "23:DURESS" and a "Happy Tune" ☺ sounds. You can now press the or button

Page 6

D-302756 13 Enroll button continuously until the red & green LEDs turn ON and then release. The PowerMax10-G2 will indicate the result on its LCD

Page 7 - 3.3 Mounting the Unit

14 D-302756 In "melody chime" mode when a chime zone is triggered, chime melody is heard 10. Press OKI to confirm. The PowerMax10-G2 disp

Page 8 - 3.4.2 PowerLink Installation

D-302756 15 Interior zones are zones within the protected premises that have nothing to do with perimeter protection. Their most important feature is

Page 9 - 4.2 Navigation

16 D-302756 Laundry room Living room Master bath Master bdrm Office (UK: Study) Upstairs Utility room Yard (UK: Garden) Custom 1 Custom 2 Custom 3 Cu

Page 10 - <OK> TO EXIT

D-302756 17 ZONE WIRING 2.2kΩ2.2kΩABC A. ZONE B. TAMPER C. ALARM Note: Do not use mains cable other than that supplied by the manufacturer (3 m long)

Page 11 - DEFINE PANEL

18 D-302756 You can now press the OKI button to delete the device of the same type, or press the button to delete a different device, or press the

Page 12 - 25:RESET OPTION

D-302756 1 PowerMax10-G2 Wireless Intrusion and Fire Alarm system Installer GuideTABLE OF CONTENTS 1. INTRODUCTION...

Page 13 - 4.4 Zones / Devices

D-302756 19 After pressing OKI, the PowerMax10-G2 display will read [chime OFF ]. 18. Press the and buttons to select between "CHIME OFF&qu

Page 14

20 D-302756 The screen will now prompt you to enter your installer code. OKI 3. Enter your Installer Code. CODE 4. Press the or button repe

Page 15 - NEXT device

D-302756 21 To Enable Siren Activation upon Telephone Line Failure 1. Make sure the system is disarmed and then press the button repeatedly until

Page 16 - 4.4.2.4 Locations

22 D-302756 8. Press OKI to confirm. The PowerMax10-G2 display will revert to [AREA CODE]. OKI OKI 9. Press the button. The PowerMax10-G2 displa

Page 17 - 4.4.3 Adding Wired Zones

D-302756 23 The screen will now prompt you to enter your installer code. 22. Enter your Installer Code. CODE 23. Press the or button repeate

Page 18 - Z01:Motion Sens

24 D-302756 38. Press the button. The PowerMax10-G2 display will read [GPRS APN] 39. Enter the name of the APN Access Point used for the inter

Page 19

D-302756 25 communication, or, temporarily connected to receive event reports only. 55. When the PowerMax10-G2 display reads [SESSION TIMEOUT], press

Page 20 - 4.5 Siren Configuration

26 D-302756 4.6.3.1 Configuring the Types of Events to be Reported 1. Make sure the system is disarmed and then press the button repeatedly until

Page 21

D-302756 27 The PowerMax10-G2 display will read [2nd RPRT METHOD]. Here you define the 2nd priority of method used to report events. If the method de

Page 22

28 D-302756 The PowerMax10-G2 display will read [RCVR 1 ACCOUNT#]. Here you enter the number that will identify your specific alarm control system to

Page 23 - AREA CODE

2 D-302756 4.9.7 Enabling Keyfob Low Battery Acknowledgement... 52 4.10 DEFINE CUSTOM LOCATIONS...

Page 24

D-302756 29 The PowerMax10-G2 display will read [IP RCVR 1]. Here you enter the IP address of the IP receiver that is located in the 1st Monitoring S

Page 25

30 D-302756 Note: A "+" can be entered at the beginning of the line by pressing and then . To enter a series of digits, use the followi

Page 26 - GPRS REPORT

D-302756 31 The PowerMax10-G2 display will read [4 attempts ]. 69. Press the or button repeatedly to select between "2 attempts"

Page 27 - 1st RPRT METHOD

32 D-302756 82. Press the OKI button. The PowerMax10-G2 display will revert to [AUTO TEST TIME]. OKI 83. Press the button. The PowerMax10-G2 dis

Page 28 - RCVR 1 ACCOUNT#

D-302756 33 The PowerMax10-G2 display will read [broadband]. Here you determine if the Broadband Module line disconnection will be reported or not an

Page 29 - PSTN/GSM RCVR1

34 D-302756 109. Press the button. The PowerMax10-G2 display will read [ZONE RESTORE]. Here you determine whether a zone restore will be reported o

Page 30

D-302756 35 8. When the PowerMax10-G2 display reads [REPORT TO PRVT], press OKI. The PowerMax10-G2 display will read [disable report]. OKI B. To

Page 31 - PSTN RPRT RETRY

36 D-302756 19. Press the OKI button and enter the third private telephone number (including area code, if required) of the private subscriber to wh

Page 32 - AUTO TEST TIME

D-302756 37 You can now press the button to take you to the "SMS REPORT TEL#" menu (see the next section), or press the button to take

Page 33

38 D-302756 Note: Every 2 crossed zones must be of the allowed zone type (Interior, Perimeter, Perimeter follower). The options are: cross zone ON an

Page 34 - PSTN UP/DOWN

D-302756 3 1. INTRODUCTION The PowerMax10-G2 is a user and installer-friendly, 29-zone fully-supervised wireless control system. The system is desig

Page 35 - REPORT EVENTS

D-302756 39 7. Press OKI and make the selection and then press OKI to confirm. The PowerMax10-G2 display will revert to [13:SWINGER STOP]. OKI SELE

Page 36 - 

40 D-302756 CODE 4. Press the or button repeatedly and select the [DEFINE PANEL] option. or 5. When the PowerMax10-G2 display reads [DE

Page 37 - 4th private tel#]

D-302756 41 Available options are: 00s (default in USA), 15s, 30s (default), 45s, 60s, 2m, 3m and 4m. Note: To comply with CP-01 requirements, "

Page 38 - 1st private tel#

42 D-302756 The PowerMax10-G2 display will revert to [33:CONFIRM TIME]. OKI You can now press the or button to program any other menu in "

Page 39

D-302756 43 To Configure the Jamming Detection 1. Make sure the system is disarmed and then press the button repeatedly until the PowerMax10-G2 di

Page 40

44 D-302756 7. Press OKI and make the selection and then press OKI to confirm. The PowerMax10-G2 display will revert to [16:NOT READY]. OKI SELECT

Page 41

D-302756 45 3. Enter your Installer Code. CODE 4. Press the or button repeatedly and select the [DEFINE PANEL] option. or 5. When the

Page 42

46 D-302756 4.8.3 Configuring Exit Delay Duration An exit delay allows the user to arm the system and leave the protected site via specific routes an

Page 43

D-302756 47 or button repeatedly until the display will read [07:QUICK ARM]. 7. Press OKI and make the selection and then press OKI to confirm. The

Page 44

48 D-302756 2. When the PowerMax10-G2 display reads [INSTALLER MODE], press OKI. The screen will now prompt you to enter your installer code. OKI

Page 45

4 D-302756 Ring Detection: The unit does not support ring detection without DC voltage present on the telephone lines. 2.5 Physical Properties Operat

Page 46

D-302756 49 4.9 User Interface Customization 4.9.1 Enabling Trouble Beeps Under trouble conditions, the sounder emits a series of 3 short beeps once

Page 47

50 D-302756 6. When the PowerMax10-G2 display reads [01:ENTRY DELAY 1], click the or button repeatedly until the display will read [10:PIEZO BEE

Page 48

D-302756 51 The screen will now prompt you to enter your installer code. OKI 3. Enter your Installer Code. CODE 4. Click the or button repe

Page 49

52 D-302756 You can now press the or button to program any other menu in "DEFINE PANEL" or press the button to take you to "<

Page 50

D-302756 53 or button repeatedly until the display will read [31:LOW-BAT ACK]. 7. Press OKI and make the selection and then press OKI to confirm.

Page 51

54 D-302756 Key Functionality Long press for speed. Places cursor to extreme right position of edit string and shows the last 16 digits of edit stri

Page 52

D-302756 55 The PowerMax10-G2 display will read [PGM: PULSE TIME]. 7. When the PowerMax10-G2 display reads [PGM: PULSE TIME], press the OKI button

Page 53

56 D-302756 The PowerMax10-G2 display will read [PGM: BY MEMORY]. 23. When the PowerMax10-G2 display reads [PGM: BY MEMORY], press the OKI button

Page 54 - 4.10 DEFINE CUSTOM LOCATIONS

D-302756 57 The PowerMax10-G2 display will read [disable ]. 39. Press the and buttons repeatedly to select between "disable", &quo

Page 55

58 D-302756 5. Press the or button to select between "no flash" and "all light flash", for example, "all light flash&quo

Page 56

D-302756 5 ABCA. SET B. LINE C. Tel line wall jack PHONE WIRING IN NORTH AMERICA RJ-31X1234567ABCDEEFFGGHHIJ KA. SET B. LINE C. RJ-31X cord D. 8-pos

Page 57

D-302756 59 6. Press OKI. The PowerMax10-G2 display will read [user code 1]. OKI 7. Press OKI and enter the 4-digit user code, for example, 68

Page 58

60 D-302756 The PowerMax10-G2 display will revert to [Remote access]. 13. Press the button. The PowerMax10-G2 display will read [Mast. downl code

Page 59

D-302756 61 The PowerMax10-G2 display will revert to [PSTN UP / DOWN]. 30. Press the button. The PowerMax10-G2 display will read [GPRS UP / DOWN]

Page 60

62 D-302756 The diagnostic test process is shown below. 5.1 Testing Devices This section describes how to test or review a device enrolled to the Pow

Page 61

D-302756 63 The first device type is displayed, "CONTACT SENSORS". OKI 4. Press the or button repeatedly to select between "CONTA

Page 62 - 5 DIAGNOSTIC TEST

64 D-302756 [SHOW RF PROBLEMS]. 3. When the PowerMax10-G2 display reads [SHOW RF PROBLEMS], press the OKI button. The PowerMax10-G2 display switches

Page 63 - 5.1 Testing Devices

D-302756 65 you to “<OK> TO EXIT” or pressing the button at the end of the procedure will take you to the "LAN" menu. The following

Page 64

66 D-302756 The following LAN messages are reported: Message Description Unit is ok Broadband Module is functioning correctly. Test aborted The d

Page 65

D-302756 67 10. Press the button. The PowerMax10-G2 display will read [FACTORY DEFIN.]. 11. Press the OKI button. The PowerMax10-G2 display rever

Page 66 - LAN RESET OPTION

68 D-302756 7. MAINTENANCE 7.1 Handling System Troubles Fault What it means Solution The control panel cannot configure or control the device. Ba

Page 67

6 D-302756 A. Network Service Provider's Facilities B. Telephone Line C. Network Demarcation Point D. RJ-31X Jack E. Telephone F. Alarm Dialing

Page 68 - WL DEVICES

D-302756 69 Fault What it means Solution A message could not be sent to the monitoring station or to a private telephone (or a message was sent bu

Page 69 - 7.1 Handling System Troubles

70 D-302756 5. When the PowerMax10-G2 display reads [FACTORY DEFLT], press the OKI button. OKI The PowerMax10-G2 display will read [<OK> to

Page 70 - 7.6 Restore Factory Defaults

D-302756 71 2. When the PowerMax10-G2 display reads [CODE _ _ _ _], enter the current installer code. CODE The PowerMax10-G2 display reads [LIST O

Page 71 - 8.1 Reading the Event Log

72 D-302756 Zone No. Zone Type Sensor Location or Transmitter Assignment (in non-alarm or emergency zones) Chime (Yes / No) 19 20 21 2

Page 72 - A1. Detector Deployment Plan

D-302756 73 Tx # Transmitter Type Enrolled to Zone Name of holder Assignment 9 10 APPENDIX B. Event Codes B1. Contact ID Event Codes

Page 73 - A2. Keyfob Transmitter List

74 D-302756 Zone # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 1st digit A A A A AAA A A A A AAAABBBBBBBBB B B B B

Page 74 - B3. 4/2 Event Codes

D-302756 75 zones, you can still enable or disable the chime function. Communicators: Refers to communication channel, for example, GSM, PSTN and br

Page 75 - APPENDIX C. Glossary

76 D-302756 APPENDIX D. DEFAULT AND PROGRAMMED ZONE DEFINITIONS Zone Zone Type Location Chime (melody No. Default Programmed Default Programmed

Page 76

www.visonic.comFully supervised wireless alarm control system Fully supervised wireless alarm control system Fully supervised wireless alarm control s

Page 77 - Industry Canada Declaration

D-302756 7 WARNING! When plugging SIREN & ZONE terminals back into place, be sure to align them carefully with the pins on the PCB. Misaligned or

Page 78

8 D-302756 4. PROGRAMMING 4.1 General Guidance We recommend programming the PowerMax10-G2 on the work bench before actual installation. Operating pow