APPENDICES
58 D-303223 PowerMaster-10/30 G2 User's Guide
Storage Temp.
Range
-4°F to 140°F (-20°C to 60°C)
-4°F to 140°F (-20°C to 60°C)
Humidity
93% relative humidity, @ 30°C (86°F)
93% relative humidity, @ 30°C (86°F)
Size
196 x 180 x 55 mm (7-5/8 x 7 x 2 in.)
266 x 201 x 63 mm (10-7/16 x 7-7/8 x 2-1/2 in.)
Weight
658g (23 Oz) (with battery)
1.44Kg (3.2 pounds) (with battery)
Color
White
White
E6. Peripherals and Accessory Devices
PowerMaster-10 G2
PowerMaster-30 G2
Modules
GSM/GPRS, IP (future use)
GSM/GPRS, IP (future use)
Additional
wireless devices
30 detectors, 8 keyfobs, 8 keypads, 4 sirens,
4 repeaters, 8 proximity tags
64 detectors, 32 keyfobs, 32 keypads, 8
sirens, 4 repeaters , 32 proximity tags
Wireless Devices
and peripherals
Magnetic Contact: MC-302 PG2, MC-302E
PG2
Motion Detectors: Next PG2; Next K9 PG2,
TOWER-20 PG2, TOWER-32AM PG2 (not UL
listed), TOWER-32AM K9 PG2 (not UL listed),
TOWER-30AM PG2, TOWER-30AM K9 PG2,
CLIP PG2 (not UL listed)
PIR Camera Detectors: Next CAM PG2;
Next CAM-K9 PG2
Smoke Detector: SMD-426 PG2, SMD-427
PG2
GSM Module: GSM-350 PG2 (optional)
Keyfob: KF-234 PG2, KF-235 PG2 (not UL
listed)
Keypad: KP-140 PG2/KP-141 PG2 (with
proximity tag), KP-160 PG2
Indoor Siren: SR-720 PG2
Outdoor Siren: SR-730 PG2
Repeater: RP-600 PG2
Gas: GSD-441 PG2 (not UL listed), GSD-442
PG2
Glass-break: GB-501 PG2 (not UL listed)
Temperature: TMD-560 PG2 (not UL listed)
Flood: FLD-550 PG2 (not UL listed)
Shock: SD-304 PG2 (not UL listed)
Note: UL requires that when using remote
smoke/CO detectors and repeaters, each
detector must be within range (STRONG) of 2
repeaters at all times (for path redundancy
UL 985).
Magnetic Contact: MC-302 PG2, MC-302E
PG2
Motion Detectors: Next PG2; Next K9 PG2,
TOWER-20 PG2, TOWER-32AM PG2 (not UL
listed), TOWER-32AM K9 PG2 (not UL listed),
TOWER-30AM PG2, TOWER-30AM K9 PG2,
CLIP PG2 (not UL listed)
PIR Camera Detectors: Next CAM PG2;
Next CAM-K9 PG2
Smoke Detector: SMD-426 PG2, SMD-427
PG2
GSM Module: GSM-350 PG2 (optional)
Keyfob: KF-234 PG2, KF-235 PG2 (not UL
listed)
Keypad: KP-140 PG2/KP-141 PG2 (with
proximity tag), KP-160 PG2
Indoor Siren: SR-720 PG2
Outdoor Siren: SR-730 PG2
Repeater: RP-600 PG2
Gas: GSD-441 PG2 (not UL listed), GSD-442
PG2
Glass-break: GB-501 PG2 (not UL listed)
Temperature: TMD-560 PG2 (not UL listed)
Flood: FLD-550 PG2 (not UL listed)
Shock: SD-304 PG2 (not UL listed)
Note: UL requires that when using remote
smoke/CO detectors and repeaters, each
detector must be within range (STRONG) of 2
repeaters at all times (for path redundancy
UL 985).
APPENDIX F. COMPLIANCE WITH STANDARDS
Compliance Statement
Hereby, Visonic Group declares that the PowerG series of central units and accessories are designed to comply with:
U.S. Standards: (FCC) CFR 47 part 15 and part 68, UL 1023 and UL 985
Canada Standards: RSS 210
European CE Standards
The PowerMaster complies with the RTTE requirements - Directive 1999/5/EC of the European Parliament and of the Council of 9
March 1999.
According to the European standard EN50131-1 and EN 50131-3, the PowerMaster security grading is 2 - "low to medium risk" and
environmental classification is II "indoor general" and the power supply type is A. EN 50131-6, and ATS4 according to EN 50136.
GSM standards:
Europe: Complies with CE standards 3GPP TS 51.010-1, EN 301 511, EN301489-7
USA: CFR 47 Part 22 (GSM850) and Part 24 (GSM 1900).
Telefication:
PowerMaster-30 G2 is certified by the Dutch testing and certification body Telefication BV to the following standards :
EN 50131-3, EN 50131-6, EN 50131-5-3, EN 50130-4, and EN 50130-5.
Telefication BV has certified only the 868 MHz variant of this product.