Visonic POWERMASTER-10 - INSTALLER GUIDE Spécifications Page 59

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 82
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 58
5. PROGRAMMING
58 D-303222 PowerMaster-10/30 G2 Installer's Guide
The following table presents the test result messages
Message
Description
Unit is OK
GSM / GPRS is functioning correctly
GSM comm. loss
GSM/GPRS module does not communicate with the Panel
Pin code fail
Missing or wrong PIN code. (Only if SIM card PIN code is enabled.)
GSM net. fail
Unit failed with registration to local GSM network.
SIM card fail
SIM not installed or SIM card failure.
GSM not detected
GSM auto enroll failed to detect GSM/GPRS module.
No GPRS service
The SIM card does not have the GPRS service enabled.
GPRS conn. fail
Local GPRS network is not available or, wrong setting to GPRS APN, user and/or password.
Srvr unavailable
PowerManage receiver cannot be reached Check the Server IP
IP not defined
Server IP #1 and #2 are not configured.
APN not defined
APN is not configured.
SIM card locked
After entering a wrong PIN code 3 consecutive times the SIM is locked. To unlock it enter a PUK
number. The PUK number cannot be entered by the control panel.
Denied by server
PowerManage denies the connection request. Check that the panel is registered to PowerManage
5.10 User Settings
This USER SETTINGS menu provides you with a gateway to the user settings through the regular user menus.
Refer to the PowerMaster User's Guide for detailed procedures.
Caution! If after having programmed the user codes the system does not recognize your installer code, this
indicates you must have programmed a user code that is identical with your installer code. If so, access the user
menu and change the code that is identical with your installer code. This will re-validate your installer code
5.11 Factory Default
The FACTORY DEFLT menu enables you to reset the PowerMaster parameters to the factory default parameters. To
obtain the relevant parameters defaults, contact the PowerMaster dealer. Reset factory default parameters as follows:
Step 1
Step 2
Step 3
Step 4
Step 5
Select "09:FACTORY DEFLT"
menu
Select "<OK> to restore"
Enter Installer Code
Resetting of factory default
parameters is underway
09:FACTORY DEFLT
<OK> to restore
ENTER CODE:
PLEASE WAIT…
to Step 1
Note: For PowerMaster with 2 installer codes, INSTALLER code and MASTER INSTALLER code, only the master
installer code enables to perform the factory default function.
5.12 Serial Number
The SERIAL NUMBER menu enables reading the system serial number and similar data for support purposes only. To
read the system serial number and other relevant data proceed as follows:
Step 1
Step 2
Step 3
Select "10:SERIAL
NUMBER" menu
[1]
Click next repeatedly to view
relevant data.
[2]
10:SERIAL NUMBER
to Step 1
Definition
0907030000.
Control panel serial number
JS702275 K16.010
Control panel software version
JS700421 v1.0.01
1
Control panel LCD software
version
PANEL ID 100005
Control panel ID for
PowerManage connectivity
PYTHON: 
GSM image transfer software
version
J-702271 K16.010
Control panel default version
1
Refers to PowerMaster-30 G2 only
Vue de la page 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 81 82

Commentaires sur ces manuels

Pas de commentaire

Robin America R600 manuels

Manuels d'utilisation et guides de l'utilisateur pour Générateurs d'électricité Robin America R600.
Nous fournissons des manuels en pdf 1 Robin America R600 à télécharger gratuitement par type de document : Spécifications


Table des matières

CONTENTS

2

1. SPECIFICATIONS

4

/ I I $

5

6

I I I I I

7

3. FEATURES

8

Fig. 4-7

9

5. SAFETY- PRECAUTIONS

10

Fig. 6- 7

11

Fig. 6-3

12

\*’ ” z

12

Ffg. 6-4

12

Fig. 6-5

13

Fig. 6-6

13

7-1 GENERATOR

14

7-2 ENGINE

15

Fig. 8- 1

17

GENERATOR OPERATION

18

8-2-3 DC OUTPUT

19

Fig. 8-3

19

Fig. 8-4

19

Fig. 8-5

19

- 16

19

Electric devices

21

Range of workable loads

21

10. MEASURING PROCEDURES

24

10-l-4 CIRCUIT TESTER

25

10-l-5 MEGGER TESTER

25

10-l-6 TACHOMETER

25

- 22

25

SWlTFf; LOAj

26

TOACd+)@ km77

26

DC TERMINAL

26

10-4-1 STATOR

27

1 O-4-2 ROTOR

27

10-4-3 CONTROL PANEL

27

FL?. 7 l-7

31

Fig. 1 l-8

31

Fi:g. 1 l-9

31

Fig. 11-10

31

11-4 IGNITION COIL

32

Resistance value

32

Measurement location

32

11-5 CONDENSER

33

11-6 RECTIFIER

33

Green Red

33

White@ [

33

Fig. 12-2

35

Sequence

36

Fig. 12-5 Fig. 12-6

37

Fig. 12-7

38

Fig. 128

38

FIQ. 10-9

38

RETAIN

39

PULL BACK

39

12-4 ASSEMBLY PROCEDURE

41

0 Precautions in Assembly

41

12-4-l GOVERNOR SHAFT

41

124-2 CRANKSHAFT

41

OPEN ENDS OF

42

PISTON RINGS

42

MAIN BEARING COVER

44

GOVERNOR GEAR

44

VALVE SPRING

46

NCE GAUGE

46

GREEN RED

48

EASE PLATE

49

Fig. 12-28)

51

Fig. 72-28

51

Fig. 72-29

53

13. TROUBLESHOOTING

54

DIAG: DIAGNOSIS

54

0.4-0.5

55

_--.. I

56

.-. .- L

57

--.I.

58

.- ._- ..-. L -._

59

‘-- ‘-1

60

-. _..-- I

61

I -.-_

61

- ----I

62

.--- - _ _

63

_ .__-.. .,.-

63

___. _

64

- .--.

65

L . . . _

65

. .-.- .L ..__..

66

T-j- --I

67

I --.

68

.._ -I -.....

69

-r--

70

Counter

72

15. WIRING DIAGRAM

74

16. MAINTENANCE

75

R&&I Generator

77

R-America, Inc

78





Plus de produits et de manuels pour Générateurs d'électricité Robin America

Modèles Type de document
EY44-2 Spécifications   Robin America EY44-2 Specifications, 75 pages
EY44-2 Spécifications   Robin America EY44-2 Specifications, 23 pages
DY30 Manuel de service   Robin America DY30 Service manual, 85 pages
R1700 Manuel de service   Robin America R1700 Service manual [en] , 52 pages
RGV12100 Manuel de service   Robin America RGV12100 Service manual, 47 pages
RGX505 Manuel de service   Robin America RGX505 Technical data [en] , 75 pages
RGV12100 Manuel de service   Robin America RGV12100 Service manual, 51 pages
EY44-2 Spécifications   Robin America EY44-2 Specifications, 43 pages
EY33-2 Spécifications   Robin America EY33-2 Specifications, 59 pages
EY33-2 Spécifications   Robin America EY33-2 Specifications, 63 pages
EY44-2 Spécifications   Robin America EY44-2 Specifications, 83 pages
RGX7800 Manuel de l'utilisateur   RGX7800 Parts GP6801 rev 0709.indd [en] , 46 pages
EY44-2 Manuel de service   Robin America EY44-2 Service manual, 31 pages
R1200 Manuel de service   Robin America R1200 Service manual, 102 pages
RGV4100 Manuel de l'utilisateur   Bakersfield, CA, 1 pages
EY33-2 Manuel de l'utilisateur   SCARABS - University of Nebraska State Museum, 35 pages