N/A = No Information Available
DMP XR150D/XR150N
The DMP XR150 and XR150N Panels provide dealers and end-users with an integrated feature package. With an extensive feature set this panel the obvious choice for all your burglary, re, and access control applications. The XR150 Series provides 10
on-board zones, up to 142 programmable zones, 106 programmable outputs, 102 programmable Form C relays, and 10,000 User Codes with 99 separate proles. The XR150N offers on-board network support. Program common areas, cross-zoned areas,
primary and secondary schedules, temporary and permanent schedules, output schedules, and view a history of up to 12,000 events. Compatible with the complete line of DMP 1100X Series Two-Way Wireless, providing support for up to 100 DMP Wireless
devices.
Compares to:
Bosh 7271GV4
Gemini X255
MAXSYS PC4020
NetworkX NX-8
Vista 128BPT
DMP XR150D DMP XR150N Bosch 7212GV4 Gemini P9600 MAXSYS PC4020 NetworkX NX-8 Vista 128BPT
Zone Information
Maximum Zones
142 142 40 96 128 48 128
Control Panel Zones
10 10 8 8 16 8 9
Control Panel Fire Zones
2 2 8 unpowered, needs module for
powered two wire smoke detectors
up to 8 two wire re zones N/A N/A 1
Hardwired Expansion Zones
132 132 32 88 N/A 48 119
Wireless Expansion Zones
DMP 1100 Series (100 Zones) DMP 1100 Series (100 Zones) 32 using Inovonics product 96 using GEM-RECV96 receiver N/A 48 127
Zone Expansion Bus(es)
Keypad (64 Zones) 1 on-board
LX-Bus (100 Zones per bus) up
to 15,000 foot bus using 710 bus
splitter repeater module and
remote power supplies. No more
than a 2 Vdc drop over entire data
bus at this distance. Use standard
18 AWG 4 conductor non-shielded
non-twisted wire.
Keypad (64 Zones) 1 on-board
LX-Bus (100 Zones per bus) up
to 15,000 foot bus using 710 bus
splitter repeater module and
remote power supplies. No more
than a 2 Vdc drop over entire data
bus at this distance. Use standard
18 AWG 4 conductor non-shielded
non-twisted wire.
32 on zonex bus 88 N/A 40 119
Zone expander modules
711/712-8/714/714-8/714-16/715/
715-8/715-16/716
711/712-8/714/714-8/714-16/715/
715-8/715-16/716
Uses Zonex and DS Mux Devices GEM-EZM8 N/A N/A Must use V-Plex Devices
Powered Smoke Zones
2 onboard, expandable to 102 2 onboard, expandable to 102 N/A N/A N/A N/A N/A
Maximum 2-Wire Smoke Detectors
12 (521B)/ 10 (2W-B, 2WT-B) per
zone, Maximum 130 zones
12 (521B)/ 10 (2W-B, 2WT-B) per
zone, Maximum 130 zones
N/A N/A N/A N/A N/A
Keypad/Access Information
Max Supervised Keypads
8 8 8 N/A 16 N/A 6
Max Unsupervised Keypads
Unlimited Unlimited 32 N/A N/A N/A N/A
Doors of Access
8 8 N/A N/A N/A N/A 8 doors using V-Plex addressable
VistaKey Access Control up to 250
cards.
Wiegand Input Keypads
Yes Yes N/A N/A N/A N/A N/A
Fully Keypad Programmable
Yes Yes Yes N/A N/A N/A N/A
Keypad Compatible with all products
Yes Yes No N/A N/A N/A N/A
Power & Output information
Auxiliary Power
1.5A 1.5A 1.4A 750 mA combined aux power and
reset relay power
N/A 1 Amp 750mA
Bell Power
1.5A 1.5A 2A N/A N/A Shared with Aux Power 1.7Amps
Maximum Ah of Batteries supported by
Control Panel
67 Amp hours of batteries
supported
67 Amp hours of batteries
supported
38Ah N/A N/A N/A 4 or 7 Ah battery
Auxiliary Output
2 Form “C” 4 Open Collector
outputs onboard expandable to 100
outputs offboard
2 Form “C” 4 Open Collector
outputs onboard expandable to 100
outputs offboard
27 3 on board expandable to 96 N/A N/A 96
DMP Product Comparisons Guide Digital Monitoring Products
14
COMPARISONS NOte